3/4" Rotogages® for Small
Stationary and Mobile LP-Gas Containers
Rotogages® are designed to provide
accurate determination of LP-Gas container contents. They may be end
or side mounted in a standard ¾" NPT coupling on stationary or mobile
containers. To guarantee accurate measurement, they should not be used
on stationary containers that exceed 60" I.D. or on mobile containers,
subject to vibration, with an I.D. of more than 24".
Features
Provides long, trouble-free performance
and ease of operation.
Polished stems assure bind-proof
operation.
Dial face is dual calibrated to provide
greater accuracy in reading contents in containers which are
not level.
NOTE: The dip tube must be cut to
the required length (½ of container inside
diameter minus ½”), when mounted on center
line of tank.
9091RM and
9092RM Series
For Small Mobile or Stationary Containers
Ordering Information
Part Number
For Container Inside Diameter
For Use With LP-Gas
For Use With NH3
For Mobile
or Stationary
Containers
For Stationary
Containers
Only
For Mobile
or Stationary
Containers
For Stationary
Containers
Only
Ellipsoidal Heads
Hemispherical Heads
Side
Mounted
End
Mounted
Side
Mounted
End
Mounted
9091RM24
-
AA9091RM24
-
30"-45"
30"-75"
30"-45"
30"-45"
9092RM36
-
AA9092RM36
-
46"-61"
76"-108"
46"-61"
46"-61"
9093TSM48*
9093RSM48
AA9093TSM48*
AA9093RSM48
62"-79"
109"-147"
62"-79"
62"-79"
9094TSM60*
9094RSM60
AA9094TSM60*
AA9094RSM60
80"-99"
-
80"-99"
80"-99"
9095TSM72*
9095RSM72
AA9095TSM72*
AA9095RSM72
100"-147"
-
100"-147"
100"-147"
* Supported Design
NOTE: The dip tube must be cut to the required length (1⁄2” of
container inside diameter minus 53⁄4”).
9090 and AA9090
Series
1” Rotogages® for Large Mobile and Stationary Containers
Rotogages® are designed to provide an accurate
determination of LPGas or anhydrous ammonia container contents. They
mount in a standard 1” NPT coupling on large mobile or stationary
containers. To operate the Rotogages®, the vent valve is opened and
the dip tube rotated slowly from the container vapor space to the
liquid space. The difference in appearance of the discharge indicates
when the liquid level is reached. Dial readings then indicate the
percentage of product in the container.
Features
Supported design
(TS Models) eliminates whipping and the need for internal
support hangers.
Resistance-free
nylon bearing inserts reduce friction and promote operating
ease.
Dial face is
dual calibrated to provide greater accuracy in reading
contents in containers which are not level.
Interchangeable accessory dials permit
interchange-able service between LP-Gas and anhydrous
ammonia.