Products > Domestic Appliances > |
|
|
Confort - Water Measurements |
| 1. Regulating the Microswitch. |
 |
|
|
 |
|
The regulation of the Micro must be made with
the tab closed. |
| |
|
Procedure: |
|
|
-
Turn the Micro screw
until it clicks (in battery-powered models until the sparks
appear).

The direction of the turn of the screw to search for this point
depends on its position in each case.
-
Starting from the previous position, give the
screw one complete turn anti-clockwise.
|
|
To check that the regulation has been performed
properly, the following conditions must be fulfilled: |
|
|
-
When the water tab is
opened, the sparks start appearing.
-
The burner switches off before closing the tap
completely.
|
|
| 2. Regulating the Hydraulic Valve. |
|
Whenever the hydraulic or gas valve
is changed it is advisable to perform the following regulation |
 |
| |
|
Turn the screw gradually, one
fourth of turn, and wait for the temperature to stabilize. Repeat
the process until reaching T1 (+5ºC). |
| 3. Water Kinetik Pressure. |
 |
| 4. Water Flows. |
 |
|